Bank = 2, 3 selects Freq, possible values are 0, 120; 20Hz,...,20KHz step = 1/12 Oct Channel1&2
Bank = 4, 5 sel. BandWidth, values 0, 59; 0.05,...,3 Oct step = 0.05 Oct Channel1&2
e. G1 30M
Bank = 0, 2, 4 sel. Gain of first 15 filters, values are 0, 60; -15, +15dB step = 0.5dB Channel 2
Bank = 1, 3, 5 sel. Gain of the following15 filters, values are 0, 60; -15, +15dB step = 0.5dB Channel 2
f. P1 30M
Bank = 0 sel. Gain of first 15 filters, possible values are 0, 60; -15, +15dB step = 0.5dB Channel 2
Bank = 1 sel. Gain of the following 15 filters, values are 0, 60; -15, +15dB step = 0.5dB Channel 2
Bank = 2 sel. Freq. of first 15 filters, possible values are 0, 120; 20Hz,...,20KHz step = 1/12 Oct Channel 2
Bank = 3 sel. Freq. of the following 15 filters, values are 0, 60, 0, 120; 20Hz,...,20KHz step = 1/12 Oct Channel 2
Bank = 4 sel. BandWidth first 15 filters, values 0, 59; 0.05,...,3 Oct step = 0.05 Oct Channel 2
Bank = 5 sel. BandWidth following 15 filters, values 0, 59; 0.05,...,3 Oct step = 0.05 Oct Channel 2
23. Control 0 50 (HP Freq)
values 0,...,120 giving HP freq: 20Hz,...,20KHz step = 1/12 Oct
24. Control 0 51 (HP Slope)
values 0,1,2 giving: bypass filter, -6dB/Oct, -12dB/Oct
25. Control 0 52 (LP Freq)
values 0,...,120 giving HP freq: 20Hz,...,20KHz step = 1/12Oct
26. Control 0 53 (LP Slope)
values 0, 1, 2 giving: bypass filter, -6dB/Oct, -12dB/Oct
Command Sequence for MIDI standard control
1. Preset change:
a. Make sure the system is not bypassed.
(Control Change: command = 0 10 value = 0)
b. Make sure the preset is of the same type as current EQ type.
(Control Change: command = 0 03 val = 0,...,5)
c. Be sure you load the preset on the correct channel.
(Control Change: command = 0 00 val = 0,...,5)
d. Load preset
Program Change: val = 0,...,127)
2. Parameter Change:
a. Make sure the system is not bypassed.
(Control Change: command = 0 10 value = 0)
b. Issue the chosen command, keeping present to work on the right bank.
(Control Change: command = 0 00 val = 0,...,5)
c. Issue Control Change: command/value
29
b. P2 15M
Bank = 0 selects Gain, possible values are 0, 60; -15, +15dB step = 0.5dB Channel 2
Bank = 1 selects Gain, possible values are 0, 60; -15, +15dB step = 0.5dB Channel 1
Bank = 2 selects Gain, possible values are 0, 120; 20Hz,...,20KHz step = 1/12 Oct Channel 2
Bank = 3 selects Gain, possible values are 0, 120; 20Hz,...,20KHz step = 1/12 Oct Channel 1
Bank = 4 selects BandWidth, possible values are 0, 59; 0.05,...,3 Oct step = 0.05 Oct Channel 2
Bank = 5 selects BandWidth, possible values are 0, 59; 0.05,...,3 Oct step = 0.05 Oct Channel 1
c. G2 15S
Bank = 0, 1, 2, 3, 4, 5 selects Gain, possible values are 0, 60; -15, +15dB step = 0.5dB Channel1&2
d. P2 15S
Bank = 0, 1 selects Gain, possible values are 0, 60; -15,+15dB step = 0.5dB Channel1&2
Vista de página 29